This 16 Fibers MTP®-16 Female with Offset Key jumper is factory terminated and fully tested in our own facility, built on OS2 9/125μm fiber with a Plenum (OFNP) jacket. It is designed for high density patching inside data center cabinets, where pre-terminated cabling saves hours of field splicing and keeps polarity under control from day one.
Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.
Product Highlights
- MTP®-16 Female (Non-Pinned) with Offset Key to MTP®-16 Female (Non-Pinned) with Offset Key, 16 Fibers
- OS2 9/125μm, G.657.A1
- Insertion loss ≤0.35dB (0.15dB Typ.), return loss ≥60dB
- Crossover polarity
- 3.0mm Plenum (OFNP) round cable
- Minimum bend radius 10mm
- Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order
Specifications
| Part Number | 16FMTPSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP®-16 Female (Non-Pinned) with Offset Key |
| Connector B | US Conec MTP®-16 Female (Non-Pinned) with Offset Key |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Polish Type | APC to APC |
| Polarity | Crossover |
| Cable Jacket | Plenum (OFNP) |
| Fiber Count | 16 Fibers |
| Glass Fiber | G.657.A1 |
| Cable Outside Diameter (OD) | 3.0mm |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Connector Durability | 500 times |
| Tensile Strength | 80/240N (Long/Short Term) |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
Applications
Use this jumper anywhere a short multi-fiber connection is needed: panel to equipment, cassette to cassette, or switch to switch within a row. The 16-fiber interface matches 400G SR8 optics, where all 16 fibers carry active transmit and receive lanes. Because it arrives polished and tested, the installer only needs to route and connect it.
Polarity and Gender Options
The same jumper can be produced with different polarity and gender combinations. Male connectors carry guide pins for direct module connection, while female versions are used at panels. Polarity A, B and C are all standard for us, and our engineers can check your link diagram if you are unsure which one to order.
Ordering Information
To order, quote 16FMTPSMF together with the length and quantity you need. The 1m (3ft) version is the standard model; Private labeling, custom packaging and project specific documentation are all handled in-house.
How We Pack
Each assembly is coiled, capped and sealed in an individual bag, then packed into foam lined export cartons. Test reports can be attached per unit or per batch, and carton marks follow your shipping instructions.
Built to Your Spec
We have manufactured fiber optic assemblies since 1995. MPO and MTP cabling is one of our core lines: fiber counts from 8 to 144, single mode and multimode, UPC and APC polish, trunk, jumper, harness and breakout formats. Send your drawing and we turn it into a ready to install assembly.
Quality and Testing
Our test routine covers insertion loss, return loss and ferrule end face inspection on every assembly. Because testing is done in-house, custom variants receive exactly the same verification as standard models.