The CAB-Q-Q-100G-5M compatible cable provides a fixed 5m (16ft) link between suitable QSFP28 to QSFP28 ports at 100G. It is built for Arista Networks host identification and is supplied as a complete DAC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.
OEM Part Number: CAB-Q-Q-100G-5MHT Part Number: CAB-Q-Q-100G-5M
| HT Part Number | CAB-Q-Q-100G-5M |
|---|---|
| Arista Networks Compatible | CAB-Q-Q-100G-5M |
| Manufacturer | HT |
| Form Factor | QSFP28 to QSFP28 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 5m (16.4ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 45mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | ≤0.5W |
| Modulation Format | 4x 25G-NRZ to 4x 25G-NRZ |
| Power Supply | 3.3V |
| MTBF | ≈50 Million Hours |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet |
| Protocols | QSFP28 MSA, SFF-8662, IEEE 802.3 |
The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is 100G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFF-8662, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 5m (16ft) length gives CAB-Q-Q-100G-5M more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
CAB-Q-Q-100G-5M is the longest of 7 verified length options in this family. Compared with CAB-Q-Q-100G-3M at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 45mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 45mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is an HT-manufactured compatible alternative for equipment that specifies Arista Networks CAB-Q-Q-100G-5M.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. CAB-Q-Q-100G-5M refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to CAB-Q-Q-100G-5M.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201