Customized OM5 Indoor Multi-Fiber Breakout Cable, LC/SC/FC/ST/LSH/Unterminated

Customized OM5 Indoor Multi-Fiber Breakout Cable, LC/SC/FC/ST/LSH/Unterminated

For Nigerian deployments, this product should be evaluated as part of the complete network path, including its connectors, mapping and acceptance values. This made-to-order multi-fiber cable is a pre-terminated indoor assembly built exactly to the configuration the project specifies: connector styles and polish at every end, fiber count, jacket rating, breakout geometry and length are all selected at order time, and the finished trunk is optically tested leg by leg before dispatch. The tight-buffered breakout construction gives each fiber its own 2.0mm or 0.9mm leg, which means the backbone trunk terminates directly into panels and hardware without a splice tray or fan-out kit.

Product Highlights

  • Available in Four Different Breakout Types
  • Available in 2.0/0.9mm Breakout Diameter
  • Available in Pulling Eye to Prevent the Cables from Twisting During the Installation Process
  • Available in LC/SC/FC/ST/LSH/Unterminated Connector
  • Available in Riser (OFNR)/LSZH/Plenum (OFNP) Flame-Retardant Jacket

Specifications

Connector TypeLC/SC/ST/FC/LSH/Unterminated
Polish TypeUPC to UPC
Fiber ModeOM5 50/125μm
Wavelength850/1300nm
Fiber Count4 Fibers
Cable JacketRiser (OFNR)/LSZH/Plenum (OFNP)
Fiber GradeBend Insensitive
Minimum Bend Radius20/10D (Dynamic/Static)
Insertion Loss≤0.3dB
Return Loss≥20dB
Attenuation at 850nm3.0dB/km
Attenuation at 1300nm1.0dB/km
Breakout Outside Diameter (OD)2.0/0.9mm
Trunk Outside Diameter (OD)7.5±0.5/4.8±0.3mm
Breakout Type0.3/0.5m Equal Breakout (Default)
Polarity (Duplex)A (Tx) to B (Rx)
Operating Temperature-10 to 60°C (14 to 140℉)
Storage TemperatureRiser (OFNR)/Plenum (OFNP): -20 to 70°C (-4 to 158°F)

OM5 and wideband multimode in the data hall

OM5 extends multimode into the wideband range: beside 850nm, the fiber carries wavelengths up to 953nm, which lets SWDM optics put four lanes on a single duplex pair. A trunk that would need four times the fiber count on OM4 runs on one OM5 assembly with the right optics, which changes the fiber-count arithmetic of a whole row. For Nigerian deployments, retaining this detail with the acceptance records supports consistent maintenance.

Pre-terminated trunks for fast hall build-outs

Data hall schedules reward pre-termination: rows are cabled in days rather than weeks when each link arrives cut to length, connectorized and tested. The backbone trunk routes once through the containment, the legs dress into the panels, and the only field work left is inspection and cleaning before inserting the connector.

Breakout geometry and why it matters

The breakout is where a trunk becomes usable. Equal-length legs suit a straight row of adjacent ports; at the same time, staggered legs reach a column of ports without slack piling up at one end. The 2.0mm legs survive patching-field handling; the 0.9mm variant suits protected routing inside panels and cassettes. Choosing the geometry at order time means the completed product arrives matching the hardware it serves.

Pulling eye and installation practice

A pre-terminated trunk is only as good as its journey through the pathway. The optional pulling eye protects the connectorized end during the pull and keeps the backbone trunk from twisting, which matters on long riser runs and congested trays. The fitting load rating on the datasheet is the number the pulling rope ought to respect, not the weight of the reel.

Planning a trunk route

A multi-fiber trunk is planned once and fitted once, which means the planning deserves the hour it takes. Measure the route through the actual containment, note the bend space at the two cable ends, and decide which end gets pulled. State the pulling eye requirement with the order if the route is long or congested. At the far end, leave the dressing slack the rack panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed before the build starts.

Pre-terminated versus field termination

Terminating OM5 fiber in the field means a splicer, a tray position, consumables and the craft time to do it well - multiplied by each fiber in the backbone trunk. A pre-terminated assembly moves all of that work to the factory floor, where polishing, inspection and testing happen under controlled conditions. The installer who receives the cable assembly routes it, dresses the legs and mates the connector interfaces; the link is ready for light the same hour. For multi-fiber counts the saving cannot be considered linear but compounding, as each field-terminated leg is another chance for a rework visit.

Fiber Count Selection

Fiber count is selected at order time: 4 Fibers, 6 Fibers, 8 Fibers, 12 Fibers, 16 Fibers, 24 Fibers are standard options for this construction. Choosing the count is a capacity decision - plan the active links, add the spares the maintenance practice calls for, and the backbone trunk arrives with each leg terminated and tested.

Custom Length Production

Stock length choices cover the common routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), 25m (82ft), with made-to-order length available beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured route length keeps the slack out of the tray and the strain off the connector interfaces.

Inspection and Test Procedures

Each trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on every fiber, and end-face geometry is inspected for consistent physical contact. The completed product ships with dust caps on every optical connector and the test results available on request.

Ordering Information and Support

Refer to this configuration by fiber mode, fiber count, connector pair, breakout geometry and length at the request stage a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, labelling or project packing - send the requirement with the enquiry and the factory will establish the build before the build starts. For Nigerian orders, our team can check the requirement before coordinating manufacture and international delivery.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201