Dell DAC-QSFP-2QSFP28-50G-3M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

Dell DAC-QSFP-2QSFP28-50G-3M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

For rack work that calls for Dell DAC-QSFP-2QSFP28-50G-3M, this page covers the 3m (10ft) version only. The 100G DAC construction connects QSFP28 to 2x SFP28 interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.

OEM Part Number: DAC-QSFP-2QSFP28-50G-3MHT Part Number: DAC-QSFP-2QSFP28-50G-3M

Product Highlights

  • Compatible alternative to Dell DAC-QSFP-2QSFP28-50G-3M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 2x SFP28
  • Fixed length and part number: 3m (10ft), DAC-QSFP-2QSFP28-50G-3M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.5W
  • Minimum bend radius: 10D/5D (Dynamic/Static)

Specifications

HT Part NumberDAC-QSFP-2QSFP28-50G-3M
Dell CompatibleDAC-QSFP-2QSFP28-50G-3M
ManufacturerHT
Form FactorQSFP28 to 2x SFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length3 (10ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius10D/5D (Dynamic/Static)
Wire AWG30AWG
Max. Power Consumption0.5W
Modulation FormatQSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ
Commercial Temperature Range0-70℃(32 to 158°F)
Application100G/50G Ethernet, 128G Fibre Channel
ProtocolsIEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 10D/5D (Dynamic/Static). These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G/50G Ethernet, 128G Fibre Channel. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 2x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

DAC-QSFP-2QSFP28-50G-3M is the longest of 3 verified length options in this family. Compared with DAC-QSFP-2QSFP28-50G-2M at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 10D/5D (Dynamic/Static); the stated power consumption is 0.5W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.

Dell Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original Dell cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Dell DAC-QSFP-2QSFP28-50G-3M.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. DAC-QSFP-2QSFP28-50G-3M refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201