HPE H3C JG331A Compatible 40G QSFP+ to 4 x 10G SFP+ Passive Copper Breakout Cable, 5m (16ft)

HPE H3C JG331A Compatible 40G QSFP+ to 4 x 10G SFP+ Passive Copper Breakout Cable, 5m (16ft)

For rack work that calls for HPE H3C JG331A, this page covers the 5m (16ft) version only. The 40G DAC construction connects QSFP+ to 4 SFP+ interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.

OEM Part Number: JG331AHT Part Number: JG331A

Product Highlights

  • Compatible alternative to HPE H3C JG331A
  • 40G connectivity at 40Gbps
  • Interface configuration: QSFP+ to 4 SFP+
  • Fixed length and part number: 5m (16ft), JG331A
  • Conductor specification: 26AWG
  • Minimum bend radius: 26mm

Specifications

HT Part NumberJG331A
HPE H3C CompatibleJG331A
ManufacturerHT
Connector TypeQSFP+ to 4 SFP+
Max Data Rate40Gbps
Minimum Bend Radius26mm
Wire AWG26AWG
Cable Length5m(16.4ft)
Jacket MaterialPVC (OFNR)
Temperature0 to 70°C (32 to 158°F)
ProtocolsSFF-8436, SFF-8431 and QSFP+ MSA

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 26mm; the jacket material is PVC (OFNR).

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431 and QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP+ to 4 SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 5m (16ft) length gives JG331A more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.

Position Within the Length Range

JG331A is the longest of 3 verified length options in this family. Compared with JG330A at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.

HPE H3C Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original HPE H3C cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies HPE H3C JG331A.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to JG331A.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201