Installers planning a 100G connection can use this 25m (82ft) AOC cable where Juniper Networks equipment specifies JNP-100G-AOCBO-25M. Its QSFP28 to 4x SFP28 arrangement arrives as one complete assembly, reducing the number of separate interfaces to handle during rack work. The physical routing notes and factory checks below apply to this exact length.
OEM Part Number: JNP-100G-AOCBO-25MHT Part Number: JNP-100G-AOCBO-25M
| HT Part Number | JNP-100G-AOCBO-25M |
|---|---|
| Juniper Networks Compatible | JNP-100G-AOCBO-25M |
| Manufacturer | HT |
| Form Factor | QSFP28 to 4x SFP28 |
| Max. Data Rate | 100Gbps |
| Cable Length | 25m (82ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W (QSFP28 End)0.8W (SFP28 Per End) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP28 MSA, SFP28 MSA |
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Longer assemblies require disciplined cable dressing. For JNP-100G-AOCBO-25M at 25m (82ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the integrated optical cable and both optical engines protected throughout the path. Within this family, JNP-100G-AOCBO-20M is shorter at 20m (66ft), while JNP-100G-AOCBO-30M is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
JNP-100G-AOCBO-25M occupies the middle of this family between JNP-100G-AOCBO-20M at 20m (66ft) and JNP-100G-AOCBO-30M at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-100G-AOCBO-25M.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. JNP-100G-AOCBO-25M refers here to 25m (82ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 25m (82ft); another length must be quoted under its corresponding part number.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201