LC UPC Quad OS2 SC Footprint Fiber Adapter with Flange

LC UPC Quad OS2 SC Footprint Fiber Adapter with Flange

For Nigerian deployments, this product should be evaluated as part of the complete network path, including its connectors, mapping and acceptance values. LC UPC Quad OS2 SC Footprint Fiber Adapter with Flange couples two LC/UPC connectors into one continuous optical path. Inside the housing, a zirconia ceramic sleeve holds the two ferrules on a common axis, keeping insertion loss low and uniform across hundreds of mating cycles. The flanged housing screws directly to the rack panel cutout for a permanent, vibration-proof mounting.

Product Highlights

  • 2x Duplex Dust Cap Keeps Adapter’s Interior Clean from Dust
  • Stainless Steel Clips for Tool-less Snap-in Installation
  • Available in A Variety of Connector Types
  • ≤0.2dB(Typical) Low Insertion Loss
  • Color Coded for Rapid Fiber Management

Specifications

Connector TypeLC-LC
Body StyleQuad
Polish TypeUPC
Fiber ModeOS2 9/125μm
Insertion Loss≤0.2dB
Durability1000 times
Mounting TypeFull Flanged
ColorBlue
Flammability RateUL 94V-0
RoHS Compliancy StatusCompliant
Operating Temperature-40 to 85℃(-40 to 185℉)
Storage Temperature-10 to 60℃(14 to 140℉)
Connector TypeLC/UPC
Body StyleQuad
Fiber ModeSM OS2
Insertion Loss≤0.2dB

Why the alignment sleeve decides adapter quality

Each optical adapter is, at heart, a sleeve alignment problem: two connector ferrules must meet on one axis with their end faces touching, and any eccentricity shows up directly as insertion loss. Zirconia ceramic is the standard sleeve material as it machines to sub-micron tolerance, resists wear across repeated matings and holds its dimensions through temperature swings. The adapters in this range use zirconia sleeves rated for insertion loss of 0.2 dB or better, which keeps an adapter pair well inside any channel loss budget.

Flanged and flangeless mounting compared

A flanged adapter fastens to the rack panel with two screws through the mounting ears: the joint is rigid, resists vibration and stays put for years, which suits frames and enclosures that move or ship. A flangeless adapter snaps into the cutout on spring latches: assembly is faster, density is higher, and a failed adapter swaps out in seconds without tools. Most panel families accept one style or the other, which means the choice follows the rack panel hardware already in the plant.

UPC and APC discipline at the adapter

The coupler has no polish of its own, but it is where polish discipline succeeds or fails: mating a UPC connector to an APC connector through any adapter damages the two end faces and wrecks return loss. Color coding exists to prevent exactly that - green housings for APC, blue for UPC single-mode - and the discipline only works when the whole plant follows it. Keep the coupler color, the interface connector boot color and the documentation consistent, and the mixing mistake becomes nearly impossible.

What adapter testing actually measures

An adapter contributes no signal of its own, which means its test is a mating test: reference connectors mate through the coupler, and the inserted loss is recorded. A zirconia-sleeve adapter ought to add no more than 0.2 dB, and the mating must repeat that figure across cycles. Durability testing runs the mating hundreds of times and re-measures - a sleeve that wears loose announces itself as creeping loss. These figures, not the housing color, are what separates an adapter that serves for years from one that becomes the mystery fault.

Selecting the right adapter for the panel

Five decisions define the coupler order: the interface connector pairing must correspond to the two sides of the mating, the mounting style must fit the rack panel cutout, the polish color code must correspond to the plant, the sleeve material must suit the behaviour grade, and the count must cover the load-out plus spares. Getting all five right at order time is what turns a bag of couplers into a dependable panel. Where the pairing crosses connector families, the hybrid range covers the common conversions.

Inspection and Test Procedures

Each adapter is inspected before packing: the sleeve bore is checked for alignment and surface finish, the housing latches are cycled for positive engagement, and sample matings from every production lot are measured for insertion loss. Accessories are checked for fit against the adapters they serve.

Ordering Information and Support

Refer to this adapter by connector pairing, mounting style, polish grade and pack quantity at the request stage a quotation. For configurations outside the listed options - mixed packs, panel hardware kits or project packing - send the requirement with the enquiry and the factory will establish the manufacturable specification. For Nigerian orders, our team can check the requirement before coordinating manufacture and international delivery.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201