For Nigerian deployments, this product should be evaluated as part of the complete network path, including its connectors, mapping and acceptance values. This OM3 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OM3 glass and optically tested as a whole assembly. The uniboot construction places the two fibers of the duplex link inside a single round 2.0mm cord with one combined connector housing, halving the cable assembly count in high-port-density panels and simplifying polarity management.
Product Highlights
- Uniboot Allows One Cable to Carry Two Fibers to Reduce Cable Congestion in High-Density Patch Fields
- Bend Insensitive Fiber with 7.5mm Min. Bend Radius
- Termination Is Tested to Ensure Network Performance
- Designed for High-Density Fiber Cabling in Network Cabinet Connections, Ceiling Wiring and Under-Floor Wiring in a Data Center
- Support for Various Transmission Speed Ethernet Applications
Specifications
| Fiber Count | 2 Fibers |
|---|---|
| Fiber Grade | Bend Insensitive Fiber |
| Fiber Mode | OM3 50/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Tensile Strength | 60/100N (Long/Short Term) |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Insertion Loss | ≤0.2dB |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70℃ (-4 to 158℉) |
| Fiber Grade | Bend Insensitive Fiber |
| Flame Rating | Riser (OFNR) |
| Insertion Loss | ≤0.2dB |
Keeping multimode links healthy
Multimode links fail more often from contamination than from fiber damage. Each ferrule must be inspected and cleaned before inserting the connector, and the dust caps ought to stay on until the moment of connection. These habits matter more than any specification on the datasheet.
OM3 for existing multimode plants
This OM3 assembly matches the fitted base of OM3 channel cabling: 10G links to 300 meters and 40/100G SR4 links to 70 meters. When the permanent link is OM3, patching with OM3 keeps the channel specification homogeneous and the test reports clean.
Polarity without re-terminating
Uniboot connectors expose the polarity through the housing rather than the termination: the latches or clips let the installer swap the fiber positions without opening the cord. A polarity mistake discovered at turn-up becomes a two-minute correction instead of a replacement order. For Nigerian deployments, retaining this detail with the acceptance records supports consistent maintenance.
Length Options
Stock length choices cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), with made-to-order length available beyond the list. Specifying the measured route length keeps the slack out of the manager and the strain off the connector interfaces.
Quality Control and Testing
Every cable assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The cable assembly ships with dust caps on the two connectors and the test result available on request.
Ordering and Factory Support
Refer to this configuration by connector pair, fiber mode and length at the request stage a quotation. For configurations outside the listed options, mixed connector families, jackets, labelling or project packing, send the requirement with the enquiry and the factory will establish the build before the build starts. For Nigerian orders, our team can check the requirement before coordinating manufacture and international delivery.