For Nigerian deployments, this product should be evaluated as part of the complete network path, including its connectors, mapping and acceptance values. This OS2 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OS2 glass and optically tested as a whole assembly. The uniboot construction places the two fibers of the duplex link inside a single round 2.0mm cord with one combined connector housing, halving the cable assembly count in high-port-density panels and simplifying polarity management.
Product Highlights
- Uniboot Allows One Cable to Carry Two Fibers to Reduce the Cable Bulk When Routing
- G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
- Push-Pull Tab for Installation and Removal with One Hand Without Needing Additional Tools
- Termination Is Tested To Ensure Network Performance
- Designed for High-Density Fiber Cabling in Network Cabinet Connections, Ceiling Wiring and Under-Floor Wiring in a Data Center
Specifications
| Fiber Count | 2 Fibers |
|---|---|
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Tensile Strength | 60/100N (Long/Short Term) |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Insertion Loss | ≤0.2dB |
| Return Loss | ≥50dB |
| Attenuation at 1310nm | ≤0.4dB/km |
| Attenuation at 1550nm | ≤0.3dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70℃ (-4 to 158℉) |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
Connector and polish choices in the single-mode plant
The OS2 interface on this jumper follows the polish discipline of the network it serves. Mixing polishes on a mated pair destroys the return loss and might damage the ferrules, which means the patch side must correspond to the rack panel side exactly. When the documentation is unclear, the boot color and the interface connector housing tell the truth: green for APC, blue or beige for UPC.
Bend tolerance in real cabinets
Patch fields are rarely kind to fiber. Cords route through tight managers, sharp tray corners and crowded vertical channels. The bend-insensitive glass in the completed assembly tolerates a 10mm fiber bend radius, which means a hurried routing decision during a night maintenance window does not itself turn into a measurable penalty on the link.
One cord, two fibers
The uniboot design merges the duplex pair into a single round cord and a single connector housing. In a 400G row where each QSFP-DD port consumes a duplex link, halving the cord count visibly changes the airflow and the manageability of the patching field.
Length Options
Stock length choices cover the common patching routes: 1m (3ft), with made-to-order length available beyond the list. Specifying the measured route length keeps the slack out of the manager and the strain off the connector interfaces.
Quality Control and Testing
Every cable assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on every cable, and end-face geometry is inspected for consistent physical contact. The cable assembly ships with dust caps on the two connectors and the test result available on request.
Ordering and Factory Support
Refer to this configuration by connector pair, fiber mode and length at the request stage a quotation. For configurations outside the listed options, mixed connector families, jackets, labelling or project packing, send the requirement with the enquiry and the factory will establish the build before the build starts. For Nigerian orders, our team can check the requirement before coordinating manufacture and international delivery.