The MCA4J80-N004 compatible cable provides a fixed 4m (13ft) link between suitable OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) ports at 800G. It is built for NVIDIA/Mellanox host identification and is supplied as a complete ACC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.
OEM Part Number: MCA4J80-N004HT Part Number: MCA4J80-N004
| HT Part Number | MCA4J80-N004 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCA4J80-N004 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 850Gbps (8x 106.25Gbps) |
| Media | Copper |
| Cable Type | Active DAC (ACC) |
| Cable Length | 4m (13ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 59.5mm |
| Max. Power Consumption | 1.3W Per End |
| Jacket Material | PET |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 |
| Application | 800G InfiniBand |
| Protocols | CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0 |
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 59.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G InfiniBand. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.
The 4m (13ft) length gives MCA4J80-N004 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
MCA4J80-N004 occupies the middle of this family between MCA4J80-N002 at 2m (7ft) and MCA4J80-N005 at 5m (16ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 59.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4J80-N004.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Keep MCA4J80-N004 associated with 4m (13ft) throughout the order and receiving record.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201