For rack work that calls for NVIDIA/Mellanox MCA4K50-X01A, this page covers the 1.5m (5ft) version only. The 1.6T ACC construction connects OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.
OEM Part Number: MCA4K50-X01AHT Part Number: MCA4K50-X01A
| HT Part Number | MCA4K50-X01A |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCA4K50-X01A |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 1600Gbps |
| Media | Copper |
| Cable Type | Active DAC (ACC) |
| Cable Length | 1.5m (5ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 50mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 2W Per End |
| Modulation Format | 8x 200G-PAM4 to 8x 200G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 1.6T InfiniBand |
| Protocols | OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0 |
The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 50mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 1.6T InfiniBand. Listed interface and protocol references include OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
The additional half metre beyond a one-metre assembly gives MCA4K50-X01A useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
MCA4K50-X01A occupies the middle of this family between MCA4K50-X001 at 1.1m (3.6ft) and MCA4K50-X002 at 2m (7ft). It adds 0.4m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 50mm; the stated power consumption is 2W Per End; the jacket material is PET.
The rated power consumption is 2W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4K50-X01A.
No. MCA4K50-X01A refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to MCA4K50-X01A.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201