NVIDIA/Mellanox MCP7F60-W05 Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Ethernet Active Copper Breakout Cable, 5m (16ft)

NVIDIA/Mellanox MCP7F60-W05 Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Ethernet Active Copper Breakout Cable, 5m (16ft)

The MCP7F60-W05 compatible cable provides a fixed 5m (16ft) link between suitable QSFP-DD to 4x QSFP56 ports at 400G. It is built for NVIDIA/Mellanox host identification and is supplied as a complete ACC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.

OEM Part Number: MCP7F60-W05HT Part Number: MCP7F60-W05

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCP7F60-W05
  • 400G connectivity at 400Gb/s
  • Interface configuration: QSFP-DD to 4x QSFP56
  • Fixed length and part number: 5m (16ft), MCP7F60-W05
  • Cable construction: Active Twinax
  • Conductor specification: 28 AWG
  • Maximum power consumption: <0.1W
  • Minimum bend radius: 80mm

Specifications

HT Part NumberMCP7F60-W05
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP56
Max Data Rate400Gb/s
Cable Length5m
Cable TypeActive Twinax
Minimum Bend Radius80mm
Wire AWG28 AWG
Jacket MaterialPVC
Power Consumption<0.1W
Modulation FormatPAM4
Inbuilt FECNo
Operating Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSASFF-8679SFF-8636

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is <0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28 AWG conductors, PVC jacket, minimum bend radius 80mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSASFF-8679SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

The 5m (16ft) length gives MCP7F60-W05 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.

Position Within the Length Range

MCP7F60-W05 is the longest of 3 verified length options in this family. Compared with MCP7F60-W04 at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 28 AWG; the minimum bend radius is 80mm; the stated power consumption is <0.1W; the jacket material is PVC.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.

NVIDIA/Mellanox Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7F60-W05.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201