OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Ethernet Active Optical Cable, 30m (98ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Ethernet Active Optical Cable, 30m (98ft)

For rack work that calls for Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT, this page covers the 30m (98ft) version only. The 400G AOC construction connects OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT

Product Highlights

  • HT-manufactured AOC assembly in 30m (98ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 30m (98ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 10W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate400Gbps
Cable Length30m (98ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption10W Per End
Modulation Format8x 50G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
Inbuilt FECYes
Application400G Ethernet
ProtocolsCMIS V4.0, OSFP MSA

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include CMIS V4.0, OSFP MSA. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The installation review for a 30m (98ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. The next shorter verified assembly is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT at 25m (82ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT is the longest of 10 verified length options in this family. Compared with OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT at 25m (82ft), it provides 5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W Per End; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.

Generic Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 30m (98ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201