OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 2.5m (8ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Passive Copper Twinax Cable, 2.5m (8ft)

The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT compatible cable provides a fixed 2.5m (8ft) link between suitable OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) ports at 400G. It is built for Generic host identification and is supplied as a complete DAC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT

Product Highlights

  • HT-manufactured DAC assembly in 2.5m (8ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 2.5m (8ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT
  • Cable construction: Passive DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 40.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive DAC
Minimum Bend Radius40.5mm
Max. Power Consumption0.1W Per End
Cable Length2.5m (8ft)
Wire AWG28AWG
Temperature Range0 to 70°C (32 to 158°F)
Jacket MaterialPVC
ProtocolsOSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0
Modulation Format8x 50G-PAM4

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT reaches both ports without tension at either connector.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2M7FT at 2m (7ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W Per End; the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.

Generic Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 2.5m (8ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201