
For rack work that calls for Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FT, this page covers the 5m (16ft) version only. The 800G AEC construction connects OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FT
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Minimum Bend Radius | 53mm |
| Power Consumption | ≤12W |
| Cable Length | 5m (16ft) |
| Wire AWG | 28AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PET |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS 5.0 |
| Modulation Format | 8x100G-PAM4 |
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is ≤12W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PET jacket, minimum bend radius 53mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
The 5m (16ft) length gives OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FT is the longest of 5 verified length options in this family. Compared with OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-4M13FT at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 53mm; the stated power consumption is ≤12W; the jacket material is PET.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AEC-5M16FT.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201