Installers planning a 400G connection can use this 30m (98ft) AOC cable where Generic equipment specifies OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FT. Its OSFP (RHS/Flat Top) to 2x QSFP56 arrangement arrives as one complete assembly, reducing the number of separate interfaces to handle during rack work. The physical routing notes and factory checks below apply to this exact length.
OEM Part Number: OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FTHT Part Number: OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FT
| HT Part Number | OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (RHS/Flat Top) to 2x QSFP56 |
| Max. Data Rate | 400Gbps |
| Cable Length | 30m (98ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 10W (OSFP End) 5.5W (QSFP56 Per End) |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | 8x 50G-PAM4 to Dual 4x 50G-PAM4 |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | CMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661 |
The listed modulation format is 8x 50G-PAM4 to Dual 4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
At 30m (98ft), OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FT should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. The next shorter verified assembly is OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-20M66FT at 20m (66ft), which is the better comparison when the managed route leaves substantial unused cable.
OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FT is the longest of 6 verified length options in this family. Compared with OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-20M66FT at 20m (66ft), it provides 10m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.
The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include CMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (RHS/Flat Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Keep OSFP (RHS/Flat Top) to 2x QSFP56-400G-AOC-30M98FT associated with 30m (98ft) throughout the order and receiving record.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201