OSFPFL-200G-QAO-20M66FT 200G OSFP 4 x 50G PAM4 RHS/Flat Top to 200G QSFP56 4 x 50G PAM4 Active Optical Cable, 20m (66ft)

OSFPFL-200G-QAO-20M66FT 200G OSFP 4 x 50G PAM4 RHS/Flat Top to 200G QSFP56 4 x 50G PAM4 Active Optical Cable, 20m (66ft)

The OSFPFL-200G-QAO-20M66FT compatible cable provides a fixed 20m (66ft) link between suitable OSFP (RHS/Flat Top) to QSFP56 ports at 200G. It is built for Generic host identification and is supplied as a complete AOC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.

OEM Part Number: OSFPFL-200G-QAO-20M66FTHT Part Number: OSFPFL-200G-QAO-20M66FT

Product Highlights

  • HT-manufactured AOC assembly in 20m (66ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to QSFP56
  • Fixed length and part number: 20m (66ft), OSFPFL-200G-QAO-20M66FT
  • Cable construction: AOC
  • Maximum power consumption: 10W (OSFP-FL End)5.5W (QSFP56 End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFPFL-200G-QAO-20M66FT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to QSFP56
Max. Data Rate200Gbps
Cable Length1m (3ft)
Cable TypeAOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP-FL End)5.5W (QSFP56 End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Modulation FormatOSFP-4x 50G-PAM4QSFP56-4x 50G-PAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE802.3cd, IEEE 802.3bs, OSFP MSA, SFF-8636

Signal and Lane Configuration

The listed modulation format is OSFP-4x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE802.3cd, IEEE 802.3bs, OSFP MSA, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

Choose OSFPFL-200G-QAO-20M66FT when the measured managed path justifies 20m (66ft), not simply to leave a large spare coil. Additional reach can simplify adjacent-rack routing, yet unused cable still needs bend-safe storage and ventilation clearance. Keep identification visible so this extended version is not confused with shorter spares. Within this family, OSFPFL-200G-QAO-15M49FT is shorter at 15m (49ft), while OSFPFL-200G-QAO-25M82FT is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

OSFPFL-200G-QAO-20M66FT occupies the middle of this family between OSFPFL-200G-QAO-15M49FT at 15m (49ft) and OSFPFL-200G-QAO-25M82FT at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP-FL End)5.5W (QSFP56 End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (OSFP-FL End)5.5W (QSFP56 End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.

Generic Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. OSFPFL-200G-QAO-20M66FT refers here to 20m (66ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Keep OSFPFL-200G-QAO-20M66FT associated with 20m (66ft) throughout the order and receiving record.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201