Cisco QSFP-100G-CU3M Compatible 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 3m (10ft)

Cisco QSFP-100G-CU3M Compatible 100G QSFP28 4 x 25G NRZ Passive Copper Twinax Cable, 3m (10ft)

The QSFP-100G-CU3M compatible cable provides a fixed 3m (10ft) link between suitable QSFP28 to QSFP28 ports at 100G. It is built for Cisco host identification and is supplied as a complete DAC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.

OEM Part Number: QSFP-100G-CU3MHT Part Number: QSFP-100G-CU3M

Product Highlights

  • Compatible alternative to Cisco QSFP-100G-CU3M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to QSFP28
  • Fixed length and part number: 3m (10ft), QSFP-100G-CU3M
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 33.5mm

Specifications

HT Part NumberQSFP-100G-CU3M
Cisco CompatibleQSFP-100G-CU3M
ManufacturerHT
Form FactorQSFP28 to QSFP28
Max Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length3m (9.84ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius33.5mm
Wire AWG30AWG
Max. Power Consumption≤0.5W
Modulation Format4x 25G-NRZ to 4x 25G-NRZ
Power Supply3.3V
MTBF≈50 Million Hours
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet
ProtocolsQSFP28 MSA, SFF-8662, IEEE 802.3

Cisco OEM Reference

Cisco classifies the QSFP-100G-CUxM family as 100GBASE-CR4 passive copper direct-attach cable for very short links within racks and between adjacent racks. Its documented family includes 1m, 1.5m, 2m, 2.5m, 3m and 5m part numbers. This HT page covers the exact length and OEM reference shown above; the compatible assembly itself follows the HT specification table.

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 33.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFF-8662, IEEE 802.3. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

QSFP-100G-CU3M occupies the middle of this family between QSFP-100G-CU2.5M at 2.5m (8ft) and QSFP-100G-CU5M at 5m (16ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 33.5mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Signal and Lane Configuration

The listed modulation format is 4x 25G-NRZ to 4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.

Cisco Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QSFP-100G-CU3M.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP-100G-CU3M refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to QSFP-100G-CU3M.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201