For rack work that calls for Generic QSFP56 to 4x SFP56-200G-DAC-2M7FT, this page covers the 2m (7ft) version only. The 200G DAC construction connects QSFP56 to 4x SFP56 interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.
OEM Part Number: QSFP56 to 4x SFP56-200G-DAC-2M7FTHT Part Number: QSFP56 to 4x SFP56-200G-DAC-2M7FT
| HT Part Number | QSFP56 to 4x SFP56-200G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP56 to 4x SFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 35mm |
| Wire AWG | 26AWG |
| Cable Length | 2m (7ft) |
| Jacket Material | PVC (OFNR) |
| Max. Power Consumption | 0.1W (QSFP56 End)0.1W (SFP56 Per End) |
| Modulation Format | QSFP56-4x 50G-PAM4SFP56-50G-PAM4 |
| DDM/DOM | Not Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472 |
The listed modulation format is QSFP56-4x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
QSFP56 to 4x SFP56-200G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
QSFP56 to 4x SFP56-200G-DAC-2M7FT occupies the middle of this family between QSFP56 to 4x SFP56-200G-DAC-1M3FT at 1m (3ft) and QSFP56 to 4x SFP56-200G-DAC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End); the jacket material is PVC (OFNR).
The rated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP56 to 4x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201