Installers planning a High-Speed connection can use this 7m (23ft) DAC cable where Generic equipment specifies SFP to SFP-High-Speed-DAC-7M23FT. Its SFP to SFP arrangement arrives as one complete assembly, reducing the number of separate interfaces to handle during rack work. The physical routing notes and factory checks below apply to this exact length.
OEM Part Number: SFP to SFP-High-Speed-DAC-7M23FTHT Part Number: SFP to SFP-High-Speed-DAC-7M23FT
| HT Part Number | SFP to SFP-High-Speed-DAC-7M23FT |
|---|---|
| Manufacturer | HT |
| Connector Type | SFP to SFP |
| Max. Data Rate | 1Gbps |
| Minimum Bend Radius | 23mm |
| Wire AWG | 26AWG |
| Cable Length | 7m (22.97ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Passive Twinax |
| Power Consumption | ≤0.1W |
| Power Supply | 3.3V |
| Operating Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | 1G Ethernet |
The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
SFP to SFP-High-Speed-DAC-7M23FT is the longest of 6 verified length options in this family. Compared with SFP to SFP-High-Speed-DAC-5M16FT at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 23mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 23mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include 1G Ethernet. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Longer assemblies require disciplined cable dressing. For SFP to SFP-High-Speed-DAC-7M23FT at 7m (23ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the complete copper assembly and both connector housings protected throughout the path. The next shorter verified assembly is SFP to SFP-High-Speed-DAC-5M16FT at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Volume orders can include customer references on the labels and carton list.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. SFP to SFP-High-Speed-DAC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to SFP to SFP-High-Speed-DAC-7M23FT.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201