SFP112 to SFP112-100G-DAC-0.5M2FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

SFP112 to SFP112-100G-DAC-0.5M2FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

Installers planning a 100G connection can use this 0.5m (2ft) DAC cable where Generic equipment specifies SFP112 to SFP112-100G-DAC-0.5M2FT. Its SFP112 to SFP112 arrangement arrives as one complete assembly, reducing the number of separate interfaces to handle during rack work. The physical routing notes and factory checks below apply to this exact length.

OEM Part Number: SFP112 to SFP112-100G-DAC-0.5M2FTHT Part Number: SFP112 to SFP112-100G-DAC-0.5M2FT

Product Highlights

  • HT-manufactured DAC assembly in 0.5m (2ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP112 to SFP112
  • Fixed length and part number: 0.5m (2ft), SFP112 to SFP112-100G-DAC-0.5M2FT
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: <0.15W
  • Minimum bend radius: 20mm

Specifications

HT Part NumberSFP112 to SFP112-100G-DAC-0.5M2FT
ManufacturerHT
Connector TypeSFP112 to SFP112
Max Data Rate100Gbps
Minimum Bend Radius20mm
Wire AWG28AWG
Cable Length0.5m (2ft)
Jacket MaterialPVC (OFNR)
Cable TypePassive Twinax
CompatibleGeneric
Power Consumption<0.15W
Power Supply3.3V
Temperature0 to 70°C (32 to 158°F)
Application100G Ethernet
Modulation Format100G-PAM4 to 100G-PAM4
ProtocolCMIS Rev5.0, SFF-8024

Signal and Lane Configuration

The listed modulation format is 100G-PAM4 to 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 100G Ethernet.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP112 to SFP112-100G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

SFP112 to SFP112-100G-DAC-0.5M2FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SFP112 to SFP112-100G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Rack Layout and Service Access

Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 20mm; the stated power consumption is <0.15W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is <0.15W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Quality Assurance and Packaging

The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.

Generic Compatibility and Factory Testing

Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Keep SFP112 to SFP112-100G-DAC-0.5M2FT associated with 0.5m (2ft) throughout the order and receiving record.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201