Installers planning a 50G connection can use this 7m (23ft) ACC cable where Generic equipment specifies SFP56-50G-ACC-7M23FT. Its SFP56 arrangement arrives as one complete assembly, reducing the number of separate interfaces to handle during rack work. The physical routing notes and factory checks below apply to this exact length.
OEM Part Number: SFP56-50G-ACC-7M23FTHT Part Number: SFP56-50G-ACC-7M23FT
| HT Part Number | SFP56-50G-ACC-7M23FT |
|---|---|
| Compatible | Generic |
| Manufacturer | HT |
| Form Factor | SFP56 |
| Max Data Rate | 50Gbps |
| Cable Type | Active Twinax |
| Max Cable Distance | Up to 7m |
| Cable Length | 7m (23ft) |
| Wire AWG | 26AWG |
| Power Consumption | ≤0.5W |
| Jacket Material | PVC |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Operating Temperature | 0 to 70℃ (32 to 158°F) |
| Modulation Technology | PAM4 |
| Bit Rate | 53.125 Gbps |
| Protocol | SFP56 MSA |
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Choose SFP56-50G-ACC-7M23FT when the measured managed path justifies 7m (23ft), not simply to leave a large spare coil. Additional reach can simplify adjacent-rack routing, yet unused cable still needs bend-safe storage and ventilation clearance. Keep identification visible so this extended version is not confused with shorter spares. The next shorter verified assembly is SFP56-50G-ACC-5M16FT at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.
SFP56-50G-ACC-7M23FT is the longest of 5 verified length options in this family. Compared with SFP56-50G-ACC-5M16FT at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 26AWG; the stated power consumption is ≤0.5W; the jacket material is PVC.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to SFP56-50G-ACC-7M23FT.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201