Customized Indoor/Outdoor Simplex OS2 LC/SC/FC/ST Fiber Optic Pigtail

Customized Indoor/Outdoor Simplex OS2 LC/SC/FC/ST Fiber Optic Pigtail

For Nigerian deployments, this product should be evaluated as part of the complete network path, including its connectors, mapping and acceptance values. This made-to-order pigtail platform is built to the ordered configuration: OS2 fiber mode, connector family, polish, jacket rating and length are all confirmed before the build starts. Each leg is factory terminated, polished and optically tested, which means the splice point inherits a connector end face that field polishing cannot match. The indoor/outdoor rating lets one assembly cross the building entry point without a transition splice.

Product Highlights

  • Optical Testing Guarantees Insertion Loss and Returns Loss
  • Meet the IEC 60794-1 and IEC 60794-2-20 Standard
  • Used for Outdoor Conduits and Corridor Cabling (No Long-term Humid Environment)
  • Feature a UV Stabilized and Moisture Resistant Outer Jacket
  • Available with LC, SC, FC, ST Connectors

Specifications

Connector ALC/SC/FC/ST UPC/APC Simplex
Connector BUnterminated
Fiber Count1 Fiber
Fiber GradeG.657.A1
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Jacket ColorBlack
Cable JacketLSZH
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long/Short Term)240/480N
Attenuation at 1310nm0.36dB/km
Attenuation at 1550nm0.22dB/km
Insertion Loss≤0.3dB
Return LossUPC≥50dB, APC≥60dB (LC/SC/ST/FC)
Operating Temperature-20 to 70°C (-4 to 158℉)
Storage Temperature-40 to 70°C (-40 to 158℉)

From raw fiber route to documented port

Each structured cabling plant ends the same way: a cable arrives at a frame, and its fibers must become ports. The pigtail is the component that makes that conversion. Spliced into a tray and presented on a panel, every strand gains a connector with a known optical signature, a position in the documentation and a place in the test record. That conversion - cable to port - is where link quality is won or lost.

Mechanical splicing as the field fallback

Where a fusion splicer cannot be considered available, mechanical splices get the link up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. The loss is higher than a fusion joint and the reflectance worse, which means the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports the two methods keeps the option open.

Ordering a customized pigtail platform

The made-to-order platform turns a catalog of options into one ordered configuration: connector family from LC, SC, FC, ST and LSH; polish as UPC or APC; jacket rating to suit the route; length to the measured run; and fiber count where the platform offers it. State the combination with the enquiry and the factory confirms the manufacturable specification before the build starts. The delivered pigtail then matches the rack panel hardware, the tray geometry and the route without field improvisation.

Configuration choices that matter at the tray

Three choices decide how a made-to-order pigtail behaves at the splice point: the interface connector family must correspond to the rack panel adapters, the polish discipline must correspond to the plant - mixing UPC and APC at one mating point destroys return loss - and the jacket rating must satisfy the pathway code. Getting these right at order time is faster than any field correction, and the factory test report then applies to the exact delivered configuration.

Crossing the building boundary without a transition

Ordinary indoor pigtails cannot legally or physically survive the outdoors; ordinary outdoor cable cannot enter the building beyond the entry point. An indoor/outdoor pigtail carries ratings for the two sides of the boundary, which means the completed product runs from the external route directly to the internal frame. Removing the traditional transition splice removes a loss point, a splice count and a documentation break from each such route.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the link margin intact after the tenth tray opening, not just at commissioning. For Nigerian deployments, retaining this detail with the acceptance records supports consistent maintenance.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame position, keep spare strands capped and bagged, and record which set went into which tray so replacement stock can readily be ordered to the identical specification.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress the cable assembly, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame position in a predictable time, and the test record maps cleanly onto the documentation. The consistency also makes quality auditable - same materials, same sequence, same pass criteria across each site.

Selecting the right pigtail for the job

Five decisions define the order: the interface connector family must correspond to the rack panel, the polish must correspond to the plant, the fiber mode must correspond to the cable assembly, the construction must correspond to the route, and the count must correspond to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the requirement sits outside the standard configurations, the made-to-order platforms cover the remaining combinations.

Inspection and Test Procedures

Each pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results available on request.

Ordering Information and Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and construction at the request stage a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the requirement with the enquiry and the factory will establish the manufacturable specification. For Nigerian orders, our team can check the requirement before coordinating manufacture and international delivery.


Get a quick quote

Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
customer service
Working hours:
Monday through Friday
AM 9:00 to PM 6:00

Buy with confidence

shipping International Shipping
We deliver the goods to worldwide customers.
iso ISO Certified
Our company is ISO 9001 certified.
payment Payment Terms
Payment terms used in our business.
warranty Products Warranty
We offer warranty for all our products.

Nigeria Fiber Optics

Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:
No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201