The QSFP-DD to QSFP-DD-800G-ACC-1.5M5FT compatible cable provides a fixed 1.5m (5ft) link between suitable QSFP-DD to QSFP-DD ports at 800G. It is built for Generic host identification and is supplied as a complete ACC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.
OEM Part Number: QSFP-DD to QSFP-DD-800G-ACC-1.5M5FTHT Part Number: QSFP-DD to QSFP-DD-800G-ACC-1.5M5FT
| HT Part Number | QSFP-DD to QSFP-DD-800G-ACC-1.5M5FT |
|---|---|
| Form Factor | QSFP-DD to QSFP-DD |
| Media | Copper |
| Max Data Rate | 800Gbps |
| Cable Type | Active DAC (ACC) |
| Cable Length | 1.5m (5ft) |
| Minimum Bend Radius | 34.5mm |
| Wire AWG | 30AWG |
| Modulation Format | PAM4 |
| Power Consumption | ≤1.2W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, SFF 8417, IEEE 802.3ck |
| Warranty | 5 Years5 Years |
| Manufacturer | HT |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, SFF 8417, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.
The additional half metre beyond a one-metre assembly gives QSFP-DD to QSFP-DD-800G-ACC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
QSFP-DD to QSFP-DD-800G-ACC-1.5M5FT occupies the middle of this family between QSFP-DD to QSFP-DD-800G-ACC-1M3FT at 1m (3ft) and QSFP-DD to QSFP-DD-800G-ACC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 34.5mm; the stated power consumption is ≤1.2W; the jacket material is PVC (OFNR).
The rated power consumption is ≤1.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to QSFP-DD to QSFP-DD-800G-ACC-1.5M5FT.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201