
For rack work that calls for Generic QSFP-DD to QSFP-DD-800G-ACC-2.5M8FT, this page covers the 2.5m (8ft) version only. The 800G ACC construction connects QSFP-DD to QSFP-DD interfaces without a separate module-and-patch-cord chain, while the stated bend and mechanical details guide a clean, serviceable installation.
OEM Part Number: QSFP-DD to QSFP-DD-800G-ACC-2.5M8FTHT Part Number: QSFP-DD to QSFP-DD-800G-ACC-2.5M8FT
| HT Part Number | QSFP-DD to QSFP-DD-800G-ACC-2.5M8FT |
|---|---|
| Form Factor | QSFP-DD to QSFP-DD |
| Media | Copper |
| Max Data Rate | 800Gbps |
| Cable Type | Active DAC (ACC) |
| Cable Length | 2.5m (8ft) |
| Minimum Bend Radius | 40.5mm |
| Wire AWG | 28AWG |
| Modulation Format | PAM4 |
| Power Consumption | ≤1.2W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, SFF 8417, IEEE 802.3ck |
| Warranty | 5 Years5 Years |
| Manufacturer | HT |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is ≤1.2W; the jacket material is PVC (OFNR).
The rated power consumption is ≤1.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, SFF 8417, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that QSFP-DD to QSFP-DD-800G-ACC-2.5M8FT reaches both ports without tension at either connector.
QSFP-DD to QSFP-DD-800G-ACC-2.5M8FT is the longest of 5 verified length options in this family. Compared with QSFP-DD to QSFP-DD-800G-ACC-2M7FT at 2m (7ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 2.5m (8ft); another length must be quoted under its corresponding part number.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201