The SFP56-50G-AOC-10M33FT compatible cable provides a fixed 10m (33ft) link between suitable SFP56 ports at 50G. It is built for Generic host identification and is supplied as a complete AOC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.
OEM Part Number: SFP56-50G-AOC-10M33FTHT Part Number: SFP56-50G-AOC-10M33FT
| HT Part Number | SFP56-50G-AOC-10M33FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP56 |
| Max Data Rate | 50Gbps |
| Cable Type | Optical Cable |
| Max Cable Distance | Up to 50m |
| Cable Length | 1m (3ft) |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤2W |
| Jacket Material | OFNP |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| FEC Function | Support Pre-FEC |
| CDR | TX+RX |
| Modulation Format | PAM4 |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocol | IEEE 802.3cd SFP56 MSA |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 60mm; the stated power consumption is ≤2W; the jacket material is OFNP.
The rated power consumption is ≤2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
This 10m (33ft) assembly is intended for routes that shorter members of the same family cannot serve comfortably. Before ordering, document the actual pathway and the space available for service access. During installation, secure the integrated optical cable and both optical engines without compressing it into an undersized bundle or leaving its weight suspended from the ports. Within this family, SFP56-50G-AOC-5M16FT is shorter at 5m (16ft), while SFP56-50G-AOC-15M49FT is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
SFP56-50G-AOC-10M33FT occupies the middle of this family between SFP56-50G-AOC-5M16FT at 5m (16ft) and SFP56-50G-AOC-15M49FT at 15m (49ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to SFP56-50G-AOC-10M33FT.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201