The SFP56-50G-AOC-50M164FT compatible cable provides a fixed 50m (164ft) link between suitable SFP56 ports at 50G. It is built for Generic host identification and is supplied as a complete AOC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.
OEM Part Number: SFP56-50G-AOC-50M164FTHT Part Number: SFP56-50G-AOC-50M164FT
| HT Part Number | SFP56-50G-AOC-50M164FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP56 |
| Max Data Rate | 50Gbps |
| Cable Type | Optical Cable |
| Max Cable Distance | Up to 50m |
| Cable Length | 1m (3ft) |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤2W |
| Jacket Material | OFNP |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| FEC Function | Support Pre-FEC |
| CDR | TX+RX |
| Modulation Format | PAM4 |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocol | IEEE 802.3cd SFP56 MSA |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is ≤2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
For this 50m (164ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. The next shorter verified assembly is SFP56-50G-AOC-30M98FT at 30m (98ft), which is the better comparison when the managed route leaves substantial unused cable.
SFP56-50G-AOC-50M164FT is the longest of 10 verified length options in this family. Compared with SFP56-50G-AOC-30M98FT at 30m (98ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 60mm; the stated power consumption is ≤2W; the jacket material is OFNP.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Neutral packaging and customer-specific packing documentation are available on request.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. Quantity and any labeling instructions should be attached specifically to SFP56-50G-AOC-50M164FT.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201