The SFP56-50G-AOC-20M66FT compatible cable provides a fixed 20m (66ft) link between suitable SFP56 ports at 50G. It is built for Generic host identification and is supplied as a complete AOC assembly. Read the routing and service-access guidance together with the specifications when preparing the installation.
OEM Part Number: SFP56-50G-AOC-20M66FTHT Part Number: SFP56-50G-AOC-20M66FT
| HT Part Number | SFP56-50G-AOC-20M66FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP56 |
| Max Data Rate | 50Gbps |
| Cable Type | Optical Cable |
| Max Cable Distance | Up to 50m |
| Cable Length | 1m (3ft) |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤2W |
| Jacket Material | OFNP |
| Receiver Type | PIN |
| Transmitter Type | VSCEL |
| FEC Function | Support Pre-FEC |
| CDR | TX+RX |
| Modulation Format | PAM4 |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocol | IEEE 802.3cd SFP56 MSA |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Extended reach changes the installation checks for SFP56-50G-AOC-20M66FT. Confirm that 20m (66ft) follows the intended route without tension, then verify that intermediate supports do not squeeze the jacket or hide the connectors behind adjacent cables. Both hosts must still match the stated interface and lane configuration. Within this family, SFP56-50G-AOC-15M49FT is shorter at 15m (49ft), while SFP56-50G-AOC-25M82FT is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
SFP56-50G-AOC-20M66FT occupies the middle of this family between SFP56-50G-AOC-15M49FT at 15m (49ft) and SFP56-50G-AOC-25M82FT at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Plan the managed route before removing the connector protection. The cable should reach both ports without tension while leaving enough space to release the latches and service adjacent interfaces. Support the run through the intended managers, keep the connector boots clear of sharp edges and avoid storing excess length in a tight coil behind warm exhaust air. For this assembly, the minimum bend radius is 60mm; the stated power consumption is ≤2W; the jacket material is OFNP.
The rated power consumption is ≤2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The completed cable is inspected at both ends, functionally tested and coiled with bend-safe slack. Protective packaging keeps the latches and boots from taking impact, while optional project labels can identify the two endpoint locations for easier field service. Standard protective packing is used by default, with project documentation arranged when requested.
Compatibility is verified as part of a complete installation check: connector inspection, host identification and an operating link. The physical cable is evaluated together with the expected OEM identity, because a connector that fits is not sufficient evidence that the host will accept and operate the assembly correctly. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
When requesting this assembly, include the exact part number and length together with the destination port types. For a rack installation, a simple port-to-port list helps us keep different lengths separate and allows any requested labels to correspond with the actual installation sequence. This page’s fixed configuration is 20m (66ft); another length must be quoted under its corresponding part number.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Thank you for the inquiry to our company; you can use this online form to leave us the message or write to sales@huihongfiber.com, we shall reply ASAP.
Working hours:
Monday through Friday
AM 9:00 to PM 6:00
Nigeria Address: Central Area, Abuja - Nigeria.
China Factory:No.55 Bldg., Tairan Block, Chegongmiao,Shenzhen
For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.
For customer support please contact:
sales@huihongfiber.com
Customer support hotline:
+86.7558339605 x 201